Experimental Study on Biomechanical Properties of Human the Anterior Longitudinal Ligament of Cervical Spine
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Objective This experimental study aimed to evaluate biomechanical properties of human cadeavaric anterior longitudinal ligament of cervical spine for potential clinical use. Methods Anterior longitudinal ligament of C1-C4?C4-T1 segments was obtained from 8 fresh Chinese cadavers to test their tensile strength using Shimadzu AUTOGRAPH electronic universal testing machine. Results Mechanical properties of anterior longitudinal ligament of C1-C4?C4-T1 segments were obtained, including maximal tensile load and strain , Lagrange tensile stress and strain, Euler stress and elastic modulus With the least square method the stress and strain of the anterior longitudinal ligament of C1-C4?C4-T1 segments were plotted by stress-strain curve. Conclusion The stress of the C1-C4 segment was greater than that of the C4-T1 segment. There were no significant difference found in strain of the anterior longitudinal ligament of different segments. The modulus of elastic of the C4-T1 segment was however greater than that of the C1-C4 segment.

    Reference
    Related
    Cited by
Get Citation

. Experimental Study on Biomechanical Properties of Human the Anterior Longitudinal Ligament of Cervical Spine[J]. Journal of medical biomechanics,2004,19(4):221-223