| |
| Finite element model testing on Coflex dynamic fixation for L4/5 and L5/S1 segment of lower lumbar |
| WU Xin-lei,WU Li-jun,ZHENG Rong-mei,WANG Ji-song,XU Hua-zi,ZHOU Yang,WU Ai-min and NI Wen-fei |
| 2013,28(5):477-483 [Abstract] [View PDF(3.63 M)] |
| |
| Biomechanical evaluation on prosthetic retention program for hemi-maxillary defects |
| CAO Min,WANG Dong-mei,WANG Ming-yi,QU Xing-zhou and ZHANG Chen-ping |
| 2013,28(5):484-489 [Abstract] [View PDF(3.77 M)] |
| |
| Development of shear force-induced intervertebral disc degeneration model |
| XIA Dong-dong,LIN Sheng-lei,ZHAO Hao-zeng,SHEN Zhong-ha,LI Yao,WANG Xiang-yang,XU Hua-zi and CHI Yong-long |
| 2013,28(5):490-495 [Abstract] [View PDF(2.77 M)] |
| |
| Experimental apparatus for measuring flow field of human upper respiratory tract with PIV technology |
| LI Fu-sheng,XU Xin-xi,SUN Dong,ZHAO Xiu-guo,LIU Zhi-guo and TAN Shu-lin |
| 2013,28(5):496-501 [Abstract] [View PDF(2.40 M)] |
| |
| Biomechanical differences of embalmed and PMMA femurs |
| WANG Jie,YANG Yang,MA Jian-xiong,MA Xin-long,XING Dan,ZHU Shao-wen,MA Bao-yi,CHEN Yang,FENG Rui and JIA Hao-bo |
| 2013,28(5):502-508 [Abstract] [View PDF(2.31 M)] |
| |
| Vortex evolution induced by jets in realistic human mouth throat model |
| SUN Dong,LI Fu-sheng,ZHAO Xiu-guo,TAN Shu-lin and XU Xin-xi |
| 2013,28(5):509-514 [Abstract] [View PDF(2.62 M)] |
| |
| Technique of automatic abdominal aortic aneurysm segmentation and 2D-mesh generation |
| LU Kun-hu and LI Zhi-yong |
| 2013,28(5):515-522 [Abstract] [View PDF(5.61 M)] |
| |
| Application of nonlinear model in analysis on viscoelastic properties of the intervertebral disc |
| LI Rui and GUO Li-xin |
| 2013,28(5):523-527 [Abstract] [View PDF(768.45 K)] |
| |
| Effects of disc displacement on stress distributions in temporomandibular joint |
| LIU Zhan,QIAN Ying-li,ZHANG Yuan-li and FAN Yu-bo |
| 2013,28(5):528-532 [Abstract] [View PDF(983.73 K)] |
| |
| Technique for measuring piezo-voltages of wet bone |
| XU lian-yun,HOU Zhen-de,FU Dong-hui and WANG Yi-han |
| 2013,28(5):533-537 [Abstract] [View PDF(904.82 K)] |
| |
| Underwater digital image measurement using lens sleeves |
| MAO Shuang-shuang,CHEN Li and ZHANG Dong-sheng |
| 2013,28(5):538-541 [Abstract] [View PDF(1.69 M)] |
| |
| Biomechanical analysis on periodontal ligament in dynamic jaw |
| LIU Wang-yu,CHEN Xue-lin,CAI Bin,XIANG Lu-sai,WU Hua-feng and HE Xu-shun |
| 2013,28(5):542-547 [Abstract] [View PDF(1.77 M)] |
| |
| Numerical simulation on an improved electro-hydraulic extracorporeal shock wave lithotripsy |
| ZHANG Xiao-yan,CHEN Jing-qiu and ZHANG Yong-xiang |
| 2013,28(5):548-553 [Abstract] [View PDF(2.27 M)] |
| |
| Effects of aqueous humor drainage to different parts of rabbit eye on intraocular pressure drop |
| QUAN Hai-ying,HUANG Yue,TIAN Bei,WANG Yan and LIU Zhi-cheng |
| 2013,28(5):554-558 [Abstract] [View PDF(1.08 M)] |
| |
| Preparation of bilayer spider silk protein vascular scaffold and its biomechanical properties and cell compatibility |
| ZHAO Liang,XU Yan-li,LI Min and CHEN Yu-qing |
| 2013,28(5):559-566 [Abstract] [View PDF(1.74 M)] |
| |
| vWF-A1A2A3-mediated rolling of circulating platelets in flows |
| YANG Xiao-fang,DING Xiao-ru,WU Jian-hua and FANG Ying |
| 2013,28(5):567-573 [Abstract] [View PDF(1.25 M)] |
| |
| Mechanical strength of biological canulated cancellous screw |
| SHI Ding-wei,GAN Yao-kai,LIANG Dong-ke,XIAO Fei,XUE Wen-dong,SUN Yue-hua,ZHU Zhen-an and DAI Ke-rong |
| 2013,28(5):574-579 [Abstract] [View PDF(895.93 K)] |
| |