In vivo Kinematic Characteristics of the Elbow during Active Flexion-Extension Motion Using Dual Fluoroscopic Imaging System
DOI:
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Objective To investigate the translation and rotation of healthy elbow joints during active flexion and extension, so as to provide references for the treatment of elbow instability and injuries. Methods Ten healthy subjects with no history of upper extremity trauma were recruited. Dual fluoroscopic imaging system (DFIS) was applied to quantify six-degree-of-freedom (6-DOF) kinematics of humeroulnar and humeroradial joint from full extension to maximum flexion in supination position. Correlation analysis was used to evaluate the relationship between the 6-DOF kinematics of the elbow joint. Results Valgus angle of humeroulnar joint gradually decreased from 15.2°±3.1° to 5.3°±2.3° with the flexion increasing. Valgus angle of humeroradical joint gradually decreased from 19.7°±4.2° to 8.2°±2.4° from full extension to maximum flexion. The valgus angle of humeroulnar and humeroradial joint was linearly related to the flexion angle during flexion and extension. The internal rotation of humeroulnar joint was quadratic nonlinearly related to the flexion angle during motion. The maximum internal rotation of the ulnar was 4.0°±4.9° at 110° flexion, and the maximum external rotation was 5.1°±4.2°. The internal rotation of humeroulnar joint gradually increased from 3.2°±16.0° to 27.2°±18.0°. Conclusions During normal flexion and extension of the elbow, the valgus angle of humeroulnar joint decreased linearly, while the internal and external rotation angle showed a nonlinear change, which first rotated internally and then rotated externally. The valgus angle of humeroradial joint decreased linearly and the internal rotation angle increased linearly. Therefore, humeroulnar joint is not a hinge joint during elbow flexion and extension. There is a kinematic difference between humeroulnar joint and humeroracial joint. For clinical treatment of complex elbow injuries, elbow instability and elbow replacement, different motion characteristics in joints should be considered to improve the outcome after surgery.

    Reference
    Related
    Cited by
Get Citation

ZOU Diyang, HU Xiangjun, HU Hai, GONG Weihua, TSAI Tsungyuan. In vivo Kinematic Characteristics of the Elbow during Active Flexion-Extension Motion Using Dual Fluoroscopic Imaging System[J]. Journal of medical biomechanics,2020,35(5):622-628

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:October 09,2019
  • Revised:November 23,2019
  • Adopted:
  • Online: October 23,2020
  • Published: October 01,2020