AN EXPERIMENTAL STUDY OF THE PRESSURE DISTRI-BUTION IN THE SUBTALAR JOINT
CSTR:
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    The Pressure distribution of the subtalar joints in ten lower legs from fresh adult cadavers werestndied. On neutral Position and under a 600 N load the contact pressures in the subtalar jointswere determined by means of the pressure sensitive film. Results showed that the average contactPressure was 19.3 1.38kgf/cm2 in the joint. There was no significant difference between thepressures of the anterior and medial and the posterior articulation (P>0.05) Meanwhile the imageof the pressure sensitive film showed that a large amount of the load was transmitted by theanterior-lateral site of the posterior articulation. Clinical significance of these data was discussed.

    Reference
    Related
    Cited by
Get Citation

. AN EXPERIMENTAL STUDY OF THE PRESSURE DISTRI-BUTION IN THE SUBTALAR JOINT[J]. Journal of medical biomechanics,1999,14(3):156-159