Abstract:Objective To explore the effects of different skull-brain interfaces and mesh density of the cerebrospinal fluid (CSF) on dynamic responses of the brain. Methods The impact kinematics on cadaver head under rotation and translation impacts were reconstructed based on the 50th percentile adult head finite element model. The interfaces between skull and CSF, CSF and brain were modeled with different types of interfaces, which were set as sharing nodes, tied, frictionless sliding, so as to investigate the effect of different interface types on dynamic responses of the brain. Then, the interfaces between CSF, skull and brain were set as sharing nodes, while CSF was divided into single-layer and tri-layer of hexahedral element with the constant thickness of CSF, to study influences of CSF with different mesh density layers on dynamic responses of the brain. Results The intracranial pressure was highly sensitive to the interface types, while the brain response seemed to be relatively insensitive to the variation in CSF layers. Conclusions The research findings provide theoretical references for the construction of CSF and the selection of skull-brain contact interface of the head finite element model.