不同槽沟方向舌侧托槽转矩控制性能三维有限元分析
DOI:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:

国家自然科学基金项目(81300903),川大-泸州战略合作项目(2013CDLZ-S22),泸州医学院科研基金项目(泸医院科[2009]5号)


Three-dimensional finite element analysis on torque performance of lingual brackets with slot in different directions
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的 分析不同槽沟方向的舌侧托槽转矩控制性能以及不同弓丝尺寸、材质对其转矩的影响规律。方法 建立上颌前牙垂直槽沟及水平槽沟舌侧托槽、3种材质(不锈钢弓丝、β钛丝、镍钛丝)、2种尺寸(0.43 mm×0.56 mm、0.41 mm×0.56 mm)弓丝的有限元模型,对左上颌中切牙施以±20°的转矩加载,分析对比其力学性能。结果 随着弓丝弹性模量的增大,不同槽沟方向的舌侧托槽转矩力矩逐渐增大;槽沟方向对舌侧托槽的转矩性能有影响,但小于弓丝尺寸及材质变化带来的影响。相同转矩角度下,垂直槽沟舌侧托槽产生约为水平槽沟舌侧托槽1~2倍的转矩力。弓丝尺寸对两种托槽转矩控制的影响小于弓丝材质,两者协同变化影响最大。结论 槽沟方向、弓丝尺寸、材质改变均能影响舌侧托槽转矩控制性能。临床应用中,可以根据所需转矩力大小,对舌侧托槽槽沟方向及弓丝尺寸、材质组合进行选择。

    Abstract:

    Objective To analyze the torque performance of lingual brackets with slots in different directions and the influence pattern of arch wires with different sizes and materials on torque of these lingual brackets. Methods The finite element models of the anterior maxilla lingual brackets with vertical and horizontal slot were constructed, including three kinds of materials (stainless steel, beta-titanium, nickel-titanium) and two sizes of arch wires (0.43 mm×0.56 mm, 0.41 mm×0.56 mm), so as to compare and analyze their mechanical properties after the application of torque load on the left upper central incisors with a rotation angle of ±20°. Results With the increase in elastic modulus of the arch wire, torque moments of lingual brackets with horizontal and vertical slot both increased gradually. Torque performance of lingual brackets was affected more by the sizes and materials of arch wires than the directions of slots. The lingual bracket with vertical slot produced 1-2 times of torque force than that with horizontal slot under the same degree of torque angle. The effect of arch wire sizes was smaller than that of arch wire materials, while the synergistic change in sizes and materials of arch wires had the largest influence on torque performance of lingual brackets. Conclusion The lingual brackets with different slot directions, sizes and materials of arch wires will influence the torque performance of lingual brackets. In clinical application, slot directions of lingual brackets as well as sizes and materials of arch wires should be adjusted properly according to the required torque force.

    参考文献
    相似文献
    引证文献
引用本文

黄跃,黄思源,瞿杨,何淞,白丁.不同槽沟方向舌侧托槽转矩控制性能三维有限元分析[J].医用生物力学,2017,32(1):54-59

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2016-01-01
  • 最后修改日期:2016-03-21
  • 录用日期:
  • 在线发布日期: 2017-03-03
  • 出版日期:
文章二维码
关闭