    目的 探讨利用应变能衰减率来确定软组织单轴拉伸的预调次数的方法。方法 以健康的新西兰大白兔的腹部皮肤为研究对象,裁取与腹白线平行(0°)、垂直(90°)两个方向上的条状试样,进行应变为15%的单轴拉伸预调实验。将获得的载荷 位移加载卸载实验数据、转换成相应的应力 应变数据,并利用MATLAB编程计算应变能衰减率η=Wn-Wn-1Wn-1×100%(Wn表示第n次预调的应变能损失),获取η分别≤5%和10%条件下的预调次数n。结果5%衰减率下,0°和90°方向上的预调次数均值分别为11.11和13.67。10%衰减率下,0°和90°方向上的预调次数分别为6.67和7.78。结论 利用应变能衰减率可以量化软组织单轴拉伸预调次数,为软组织生物力学测试的标准化提供了研究基础。

    Abstract:

    Objective To investigate a method determining the number of preconditioning cycles in uniaxial tensile test on soft tissues by calculating the decay rate of strain energy. Methods The abdominal skin of healthy New Zealand rabbits was selected as study object, from which strip specimens were obtained in directions parallel to linea alba (0°)and perpendicular to linea alba(90°). Then the uniaxial preconditioning tests with 15% preconditioning strain were performed on these specimens. Load displacement preconditioning data were obtained, and transformed into the stress strain data correspondingly. The preconditioning cycles (n values), at the decay rate of strain energy being 5% and 10%, respectively, were then calculated by MATLAB programme when n values satisfy the inequality η=Wn-Wn-1Wn-1×100%≤5% or≤10%(Wn signifies the strain energy loss in the nth preconditioning cycle). Results When the decay rate of strain energy was 5%, the number of preconditioning cycles in 0° and 90° direction was 11.11 and 13.67, respectively. When the decay rate of strain energy was 10%, the number of preconditioning cycles in 0° and 90° direction was 6.67 and 7.78, respectively. Conclusions By calculating the decay rate of strain energy, the number of preconditioning cycles in uniaxial tensile on soft tissues can be quantified, which could help provide the research basis for standardization of biomechanical testing on soft tissues.

    参考文献
    相似文献
    引证文献
引用本文

王辉,乔媛慧,刘志成.利用应变能衰减率确定软组织单轴拉伸预调次数[J].医用生物力学,2013,28(6):602-605

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2012-11-13
  • 最后修改日期:2012-12-18
  • 录用日期:
  • 在线发布日期: 2013-12-06
  • 出版日期:
文章二维码
关闭