侧向冲击载荷作用下股骨-骨盆复合体的生物力学响应
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:

国家科技支撑课题(2008BAI68B06),上海交通大学 “医工(理)交叉研究基金”项目(YG2010MS09)


Biomechanical response of the pelvis femur complex under lateral pelvic impacts during sideways falls
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的 利用三维有限元分析方法研究股骨 骨盆复合体在人体侧向摔倒时冲击载荷作用下的生物力学行为特性。方法 基于中国力学虚拟人模型库建立股骨-骨盆-软组织复合体的三维有限元模型,包括皮质骨、松质骨和软组织;同时,构建一个刚体平面仿真地面。约束地面刚体,对整个股骨-骨盆-软组织复合体模型施加侧向2 m/s的速度载荷,整个仿真分析时间设定为20 ms。通过三维有限元分析计算获得股骨-骨盆侧摔冲击过程中应力应变变化特性。结果 在13 ms时,股骨大转子处软组织与地面的接触力达到最大值7 656 N,对应的骨盆软组织上的最大等效应力值为2.64 MPa。冲击过程中,耻骨联合处骨皮质上等效应力出现极大值,为142.64 MPa,接近其屈服强度; 股骨颈和大转子处应力水平较高,股骨颈处皮质骨上的最大等效应力值为76.49 MPa;股骨颈处松质骨上的最大等效应力值为8.44 MPa,最大压缩应变值为0.94%;股骨大转子处松质骨上的最大等效应力值为8.50 MPa,最大压缩应变值为0.93%。结论 人体股骨-骨盆复合体在侧摔减速冲击载荷作用下股骨颈、大转子及耻骨联合处易出现骨折。

    Abstract:

    Objective To investigate the biomechanical characteristics of the human pelvis-femur complex under lateral pelvic impacts during sideways falls using three dimensional (3D) finite element (FE) method. Methods Based on the model database of China Mechanical Virtual Human, a 3D FE model of the pelvis femur soft tissue complex was created, including cortical bone, cancellous bone and soft tissue capsule. A rigid plane model was also constructed for ground simulation and constrained in all freedoms. The average hip lateral impact velocity of 2 m/s was applied to the model and the time for simulation analysis was set at 20 ms. The stress and strain distribution on the pelvis-femur complex were obtained by the 3D FE calculation and analysis. ResultsOn the contact surface, the peak impact load reached to 7 656 N at 13 ms, while the maximum Von Mises stress on the soft tissue was 2.64 MPa. Simultaneously, the peak Von Mises stress of 142.64 MPa on the cortical bone occurred in the region of pubic symphysis, which was approximate to the yield stress on the cancellous bone. The Von Mises stress level was higher in the region of the femur neck and greater trochanter. At 13 ms, the peak Von Mises stress on the cortical bone of the femur neck was 76.49 MPa and that on the cancellous bone was 8.44 MPa with the peak compressive principal strain being 0.94%. The peak Von Mises stress on the cancellous bone of greater trochanter was 8.50 MPa, while the peak compressive principal strain was 0.93%. Conclusions Bone fractures of the pelvis-femur complex tend to occur in the region of the femur neck, greater trochanter and pubic symphysis under deceleration impacts during sideways falls.

    参考文献
    相似文献
    引证文献
引用本文

王冬梅,董谢平,张琳琳.侧向冲击载荷作用下股骨-骨盆复合体的生物力学响应[J].医用生物力学,2011,26(6):502-507

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2011-02-24
  • 最后修改日期:2011-04-27
  • 录用日期:
  • 在线发布日期:
  • 出版日期:
文章二维码
关闭