两种人造心血管生物力学性能的比较
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:


Study on biomechanical characteristics of artificial heart prostheses
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的对法国产InterGard针织人造心血管和苏州产机织人造心血管这两种人造心血管试样的力学性能进行测试,为人造血管的研制及临床应用提供参考。方法对两种人造心血管试样分别进行拉伸强度、应力应变、应力松弛以及蠕变的力学性能测试,并对结果进行统计分析处理。结果法国产InterGard针织人造心血管的力学性能优于苏州产机织人造心血管的力学性能结论人造心血管的力学性能主要取决于它所用的材料、结构等因素。

    Abstract:

    Objective To determine the biomechanical properties of two kinds of artificial heart prostheses (made in France (InterGard) and made in Suzhou, respectively) and provide theoretic reference for its manufacture and clinical use. Method Tensile strength, stress-strain relationship, stress relaxation and creep of these specimens were tested by using a material testing machine and analyzed the results.R esult The specimens made in France are superior in its properties compared with that of the specimens made in Suzhou.C onclusion Biomechanical properties of artificial heart prostheses mainly depend on the the material it is made of and the factures such as its stuff, structure, etc.

    参考文献
    相似文献
    引证文献
引用本文

李晓阳,呼春晖,曾衍钧,黄福华,郑军,孙立忠.两种人造心血管生物力学性能的比较[J].医用生物力学,2008,23(4):284-287

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期:
  • 出版日期:
关闭