密质骨损伤机理的实验研究
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:


AN EXPERIMENTAL STUDY ON THE DAMAGE MECHANISM OF COMPACT BONE
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    用Instron试验机对新鲜人股骨密质骨试样进行了一维拉伸实验研究,利用实验结果对由平行粘弹性杆系统建立的密质骨损伤本构模型待定参数进行拟合,获得了较高的相关系数(R≥0.90)和较好的显著性水平(α≤0.01)。此外,对拉伸试样破坏断面进行扫描电镜(SEM)观察和分析。实验发现,在准静态加载情形下,微裂纹沿着粘合线扩展,骨单位被从骨组织中拔出,并呈粘性特征。

    Abstract:

    Tests in tension at strain rates from 4.0 ×10 ̄-5/s to 9.0×10 ̄-3/s are performed on wet human compact bone specimens by the Instron Testing Instrument. The unknown parameters in the damage model based on the parallel viscoelastic bar system are determined by experimental data and the higher correlation coefficient (R≥0.90) is obtained. The fracture surfaces of the specimens are observed and analyzed by scanning electron microscope. The results indicate that, under the quasi-static loading condition, microfractures propagate through cement lines and Haversian osteons are pulled out of bone matrix, just as a creep move. This shows that the damage mode of the sequential pull-out of the osteons from bone matrix is reasonable.

    参考文献
    相似文献
    引证文献
引用本文

张瑞萍,吴文周.密质骨损伤机理的实验研究[J].医用生物力学,1996,11(2):83-86

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期:
  • 出版日期:
关闭