锁骨骨折复位拉伸力优化加载方案的模拟分析
DOI:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:

国家自然科学基金项目(51365006, 51445013),广西科学研究与技术开发技术项目课题(桂科攻0632007-2E)


Simulation analysis on optimial loading scheme of resetting tensile stress for clavicular fractures
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的 探讨锁骨骨折复位拉伸力的外部加载最优方案,为锁骨骨折外固定器的优化设计提供力学参考。方法 利用志愿者肩部CT扫描数据通过Mimics软件建立人体左侧肩部的三维模型。为了更好地模拟实际人体肩部,在模型中添加韧带组织并考虑肌肉组织的约束,建立复位拉伸力模拟分析的实验模型。通过3组仿真实验,分别模拟分析复位拉伸力方向、作用点位置的影响及取值范围,采用正交试验法综合模拟多种外部载荷情况下人体肩部模型锁骨部位获得的复位拉伸力。结果 当外固定器加载在肩部合力方向在水平面的投影与冠状轴的夹角 >45°时,锁骨获得复位拉伸力,且随着夹角越大拉伸力越大。外固定器加载在肩部合力方向在矢状面的投影与矢状轴的夹角 =30°~45°时,锁骨复位拉伸力最大。外固定器在肩部作用的位置离锁骨水平位置越远,锁骨复位拉伸力就越大。结论 正交试验结果表明,产生最佳复位拉伸力的参数组合为θ=65°, η=50°,施加在人体肩部肱骨头中心。

    Abstract:

    Objective To investigate the optimal scheme about the external loading of resetting tensile stress for clavicular fractures, so as to provide some mechanical references for optimal design of external fixators for clavicular fractures. Methods The shoulder CT scanning data from a volunteer were used to establish the three-dimensional model of human left shoulder by Mimics software. In order to better simulate the actual human shoulder, the ligament tissues were added in the model and the constraints of muscles were considered, and the experimental model for simulation analysis on resetting tensile stress was established. By 3 simulation experiments, the impacts from directions of resetting tensile stress, positions of action points and value ranges were simulated and analyzed, respectively. The resetting tensile stresses obtained from clavicle of the shoulder model under various external loading cases were simulated by orthogonal test methods. Results When the (angle between the horizontal plane projection of shoulder force which was loaded by external fixator and the coronal axis ) was greater than 45°, clavicle could obtain the resetting tensile stress, which became greater with the angle increasing. When (angle between the sagittal plane projection of shoulder force which was loaded by external fixator and the sagittal axis) was 30°-45°, the resetting tensile stress of clavicle was the maximum. The farther the position on which the loads from external fixator was exerted from the horizontal position of clavicle, the larger the resetting tensile stress of clavicle was. Conclusions The results of orthogonal test show that the optimal resetting tensile stress is produced with parameter combination of θ=65°, η=50°, acting on the center of humerus head of the shoulder

    参考文献
    相似文献
    引证文献
引用本文

赵永信,李欣欣,李鼎斌,毛汉领,陈邑,易忠安.锁骨骨折复位拉伸力优化加载方案的模拟分析[J].医用生物力学,2017,32(3):242-247

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2016-06-29
  • 最后修改日期:2016-09-03
  • 录用日期:
  • 在线发布日期: 2017-06-28
  • 出版日期:
文章二维码
关闭