    摘要:

    目的 采集上、下楼梯过程中健康人体下肢运动学、动力学功能参数,为外骨骼助行器实现上、下楼梯这一运动形式的步态轨迹设计和驱动元件选型提供数据支持。方法 设计常规楼梯实验装置,利用三维运动捕捉系统和三维测力台系统同步测量方法测量上、下楼梯时踝、膝、髋关节运动信息,应用SPSS统计软件和Origin绘图软件分析下肢运动特点,并对比分析上、下楼梯时下肢的功能参数。结果 通过实验获得健康青年人在上、下楼梯时下肢关节在矢状面关节角度、关节力矩随步态变化规律及活动极限值,上楼时踝、膝、髋关节角度依次为-10.66°~13.26°、6.85°~88.92°、1.31°~50.18°,下楼时踝、膝、髋关节角度依次为-37.42°~27.18°、9.83°~95.53°、8.01°~31.62°。上、下楼梯时所需最大踝、膝、髋关节力矩依次为1.788、1.121和0.946 N?m/kg。结论 上、下楼梯时人体下肢步态参数随步态变化趋势与关节运动范围显著不同。助行器步态规划要针对上、下楼梯单独设计,驱动元件的选型上要满足上、下楼梯时各关节的最大力矩需求。

    Abstract:

    Objective To collect the kinematics and kinetics functional parameters of healthy human lower limbs during stair ascent and descent, so as to provide data for designing the gait trajectory and selecting the driving components of the exoskeleton walker to achieve the motion of stair climbing. Methods Common staircase as an experimental setup was designed, and the three-dimensional (3D) motion capture system and 3D force plate were used to simultaneously measure the ankle, knee, hip motion information during stair ascent and descent. The movement characteristics of the lower limb during stair climbing was analyzed by SPSS statistical software and Origin graphics software, and the functional parameters during stair ascent and decent were also compared and analyzed. Results The joint angle at the sagittal plane, joint moment variation with gait and activity limits in lower limbs of healthy youth during stair ascent and descent were obtained by the experiment. The ranges of motion in ankle,knee and hip joints during stair ascent were -10.66°-13.26°, 6.85°-88.92°, 1.31°-50.18°,while those during stair descent were -37.42°-27.18°,9.83°-95.53°,8.01°-31.62°.The maximum ankle, knee and hip joint moment during stair ascent and descent were 1.788, 1.121, 0.946 N?m/kg, respectively. Conclusions The gait parameters variation with gait and the joint range of motion in human lower limb were significantly different during stair ascent and descent. Separate design targeting at stair ascent or stair descent is required for gait planning of walking aids, and the selection of driving element should consider the maximum moment in each joint during stair ascent and descent.

    参考文献
    相似文献
    引证文献
引用本文

张峻霞,窦树斐,苏海龙,曹琳.上、下楼梯步态参数变化特征研究[J].医用生物力学,2016,31(3):266-271

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2015-09-28
  • 最后修改日期:2015-11-23
  • 录用日期:
  • 在线发布日期: 2016-06-29
  • 出版日期:
文章二维码
关闭