颈胸段脊柱全脊椎切除术后不同重建方式的有限元分析
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:

国家自然科学基金资助项目(51106099),上海市教委科研创新项目(12YZ109)


Finite element analysis on different spine reconstruction methods after total spondylectomy of cervicothoracic spine
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的 基于CT图像对人体颈胸段脊柱C5~T2节段进行三维模型重建,采用有限元方法探究椎弓根螺钉、钛网和钢板等不同内固定器械组合对颈胸段脊柱全脊椎切除(total spondylectomy, TS)术后稳定性的影响及内固定器械的应力分布。方法 建立颈胸段脊柱C5~T2节段健康完整模型,并通过与体外实验关节活动度(range of motion, ROM)结果对比验证模型有效性。在健康完整模型基础上,建立颈椎C7节段行TS后的4种重建模型:TM+AP+DPS模型(钛网+前路钢板+后路双节段椎弓根螺钉固定),TM+AP+SPS模型(钛网+前路钢板+后路单节段椎弓根螺钉固定);TM+DPS模型(钛网+后路双节段椎弓根螺钉固定);AP+DPS模型(前路钢板+后路双节段椎弓根螺钉固定),并分析各重建模型在前屈、后伸、左右侧弯和左右扭转时的ROM及内固定器械的应力分布情况。结果 TS术后重建会大幅度降低重建节段ROM,模型的重建节段ROM均下降超过93%,后路单节段螺钉固定时,钛网出现应力集中现象。结论 4种模型重建节段固定效果相近,后路双节段螺钉固定的3种模型中内固定器械应力分布较为平均,模型整体稳定性优于后路单节段固定模型。

    Abstract:

    Objective To establish 3D finite element of human cervicothoracic spine C5-T2 based on CT images, and explore effects on stability of the cervicothoracic spine after total spondylectomy (TS) by using various combinations of internal fixation devices (pedicle screw, titanium mesh, steel plate), including the stress distributions on these internal fixation devices. Methods The intact finite element model of cervicothoracic spine C5-T2 was established and validated by comparing the model’s range of motion (ROM) with that of other in vitro experiments. Then four reconstruction models after TS of cervical spine segment C7 were established: TM+AP+DPS model (titanium mesh + anterior plate + posterior double-segmental pedicle screw), TM+AP+SPS model (titanium mesh + anterior plate + posterior single-segmental pedicle screw), TM+DPS model (titanium mesh + posterior double-segmental pedicle screw), AP+DPS model (anterior plate + posterior double-segmental pedicle screw). ROM of each reconstruction model under flexion, extension, lateral bending and rotation and stress distributions on these internal fixation devices were then analyzed. Results ROM of the reconstruction segments was greatly reduced by over 93% as compare to that of the intact model. Stress concentration phenomenon appeared on the titanium mesh in the TM+AP+SPS model. Conclusions The fixation effects of four reconstruction models are similar. Stresses on 3 DPS fixed-models are more evenly distributed, indicating that the overall stability of DPS fixed-model is superior to that of SPS fixed-model.

    参考文献
    相似文献
    引证文献
引用本文

方新果,赵改平,王晨曦,柏磊磊,陈二云,赵庆华.颈胸段脊柱全脊椎切除术后不同重建方式的有限元分析[J].医用生物力学,2015,30(3):220-225

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2014-06-05
  • 最后修改日期:2014-07-02
  • 录用日期:
  • 在线发布日期: 2015-06-24
  • 出版日期:
文章二维码
关闭