Measurement of articular cartilage in water based on nanoindentation method
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的 在保持关节软骨表面湿润的情况下,进行纳米压痕实验,研究具有一定生物活性的关节软骨微结构的力学性能。方法 通过实验的方法,评估冷镶嵌法和保湿法对保持软骨在体力学性能的优劣,并应用保湿法得到不同保护液下软骨微结构的力学性能。结果 冷镶嵌法测得的软骨表层的弹性模量远大于保湿法测得的数值,蒸馏水保护下的软骨表层和深层的弹性模量明显高于壳多糖溶液和生理盐水保护下的软骨的弹性模量。结论 保湿法更有利于保持生物材料在体时的力学性能和保持生物材料的生物活性,通过保湿法也可以证明壳多糖溶液及生理盐水均可有效保持软骨的力学性能。

    Abstract:

    Objective To study mechanical properties of the microstructure of the articular cartilage with biological activity by nanoindentation tests under the condition of keeping the articular cartilage in water. Methods The different abilities to keep in situ mechanical properties of the articular cartilage with cold mosaic method or with moisturizing method were evaluated by experiments, and the mechanical properties of the microstructure of the articular cartilage in different kinds of solution used in moisturizing method were also obtained. Results The experiment showed that the elastic modulus on the cartilage surface layer with cold mosaic method was much higher than that with moisturizing method, and the elastic modulus on the cartilage surface and deep layer in chitosan and saline were much lower than that in distilled water. Conclusions The moisturizing method is better at preserving in situ mechanical properties and biological activity of the biological materials, and chitosan and saline are proved to have the effect of keeping mechanical properties of the cartilage used in moisturizing method.

    参考文献
    相似文献
    引证文献
引用本文

刘志远,杨庆生.基于纳米压痕法的关节软骨保湿测量技术[J].医用生物力学,2011,26(5):408-412

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2011-09-01
  • 最后修改日期:2011-09-20
  • 录用日期:
  • 在线发布日期:
  • 出版日期:
文章二维码
关闭